The birdsmouth is one of the most important cuts on a common rafter. Get the seat depth wrong and the rafter rocks. Cut too deep and you violate code. Here’s how to lay it out right.
A birdsmouth cut is a notch where the rafter bears on the wall top plate. It has a plumb (heel) cut running vertical and a seat (level) cut running horizontal. Seat depth = plate width × sin(pitch angle). Leave at least two-thirds of the rafter depth above the notch — IRC R802.7.1 limits the seat cut to one-third the rafter depth.
The heel cut runs vertical when the rafter is in position. It is the same angle as the ridge plumb cut at the top of the rafter — arctan(rise/12). For 6:12: 26.6°. This cut is the face of the notch that faces the ridge.
The seat cut runs horizontal when the rafter is in position. It’s the surface that bears on the top plate. The length of the seat cut matches the plate width — typically 3½″ for a doubled 2×4 plate or 5½″ for a doubled 2×6 plate. The two cuts meet at a right angle at the bottom corner of the notch, forming the “beak” of the bird.
Seat depth is the vertical dimension of the notch, measured from the top of the seat cut to the top edge of the rafter. This is what determines how much rafter remains above the plate — the HAP (Height Above Plate).
Formula: Seat depth = plate width × sin(plumb cut angle)
For a 6:12 pitch on a 3½″ plate: sin(26.6°) = 0.447 × 3.5 = 1.565″ (≈ 1-9/16″)
| Pitch | Angle | Seat Depth (3½″ plate) | Seat Depth (5½″ plate) |
|---|---|---|---|
| 3:12 | 14.0° | &frac7″8″ | 1-5/16″ |
| 4:12 | 18.4° | 1-1/16″ | 1-11/16″ |
| 5:12 | 22.6° | 1-5/16″ | 2-1/16″ |
| 6:12 | 26.6° | 1-9/16″ | 2-7/16″ |
| 7:12 | 30.3° | 1-13/16″ | 2-13/16″ |
| 8:12 | 33.7° | 2-1/16″ | 3-3/16″ |
| 9:12 | 36.9° | 2-5/16″ | 3-9/16″ |
| 10:12 | 39.8° | 2-1/2″ | 3-15/16″ |
| 12:12 | 45.0° | 2-15/16″ (max 2-7/16″ for 2×8) | 3-7/8″ |
IRC R802.7.1 seat depth limit: The birdsmouth seat cut cannot exceed one-third of the rafter depth. For a 2×8 rafter (7¼″ actual), the maximum seat cut is 2.42″ (7.25 ÷ 3). At 12:12, a 3½″ plate produces a 2.47″ seat — slightly over the limit for a 2×8. Either use a 2×10 rafter or reduce the plate seat to stay compliant.
HAP is the distance from the top of the wall plate to the top edge of the rafter at the birdsmouth. It determines where the rafter tail sits relative to the wall and affects the soffit height. HAP must be consistent across all rafters for the fascia and soffit to align.
HAP = Rafter depth − seat depth
For a 2×8 rafter (7¼″) at 6:12 on a 3½″ plate: HAP = 7.25 − 1.5625 = 5.69″ (≈ 5-11/16″)
When mixing rafter sizes on the same building (e.g., 2×6 vs 2×8 in different sections), HAP will differ between sections unless the seat depths are adjusted. Matching HAP across rafter sizes means intentionally cutting a deeper seat on the smaller rafter — as long as it stays within the one-third rule.
Enter pitch and lumber size — get seat depth, seat width, HAP, and a code check.
The birdsmouth is cut with a circular saw for the plumb cut and the seat cut. A few rules:
If the rafter tips or rocks when set on the plate, the seat cut is not level (horizontal). The most common cause is the saw bevel not being reset to 0° for the seat cut after being set to the plumb angle. Check the seat cut with a level and recut if needed.
A gap between the heel cut face and the plate means the plumb cut angle is slightly off. A 1° error in the plumb angle produces roughly a 1/8″ gap on a typical birdsmouth. Recut at the correct angle. Small gaps can be shimmed but should not exceed 1/4″.
If the seat depth exceeds one-third of the rafter depth, the rafter must be replaced or reinforced. A common fix is to install a ledger alongside the rafter to restore bearing area, but this requires engineering review. The better approach: calculate correctly before cutting.
HAP variation across rafters causes the fascia to be uneven and the soffit line to wave. The fix is to cut a pattern rafter first, verify the HAP, then trace all subsequent birdsmouths from the pattern. Do not re-measure each rafter individually.
When the wall plate configuration changes — say, a double 2×4 plate on a standard wall (3½″) versus a double 2×6 plate on an exterior wall (5½″) — the birdsmouth seat length changes but the seat depth formula remains the same. The wider plate just means a longer seat cut, not a deeper one.
How deep should the birdsmouth seat cut be?
Seat depth = plate width × sin(plumb cut angle). For a 6:12 pitch on a 3½″ plate: sin(26.6°) × 3.5 = 1.57″ (1-9/16″). The IRC limits seat depth to one-third of the rafter depth (IRC R802.7.1).
What is HAP in roof framing?
HAP stands for Height Above Plate — the vertical distance from the top of the wall plate to the top edge of the rafter at the birdsmouth location. HAP = rafter depth minus seat depth. All rafters should have the same HAP for a level fascia and soffit.
Can I cut the birdsmouth seat too deep?
Yes. IRC R802.7.1 limits the seat cut to one-third of the rafter depth. For a 2×8 rafter (7-1/4″), the maximum seat depth is 2.42″. Exceeding this structurally weakens the rafter at the bearing point.
Why does my rafter rock on the plate?
The seat cut is not level (horizontal). Most likely cause: the saw bevel was not reset to 0° for the seat cut after being set to the plumb angle. Check with a level and recut the seat flat.
What angle do I set my saw for a birdsmouth on a 6:12 roof?
Set the bevel to 26.6° for the heel (plumb) cut, and 0° for the seat (level) cut. The two cuts are different angles; failing to reset the bevel between them is the most common birdsmouth cutting error.